<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Greenhouse Gas | AMOF</title>
	<atom:link href="https://amof.ac.uk/instrument_category/greenhouse-gas/feed/" rel="self" type="application/rss+xml" />
	<link>https://amof.ac.uk</link>
	<description>Atmospheric Measurement and Observation Facility</description>
	<lastBuildDate>Mon, 01 Apr 2024 09:10:29 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://amof.ac.uk/wp-content/uploads/2020/02/cropped-AMOF-Icon-Colour@4x-32x32.png</url>
	<title>Greenhouse Gas | AMOF</title>
	<link>https://amof.ac.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Los Gatos Ultraportable Greenhouse Gas Analyzer</title>
		<link>https://amof.ac.uk/instruments/los-gatos-ultraportable-greenhouse-gas-analyzer/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Mon, 16 Nov 2020 10:10:14 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=2925</guid>

					<description><![CDATA[The Ultraportable Greenhouse Gas Analyzer (UGGA) reports measurements of methane, carbon dioxide and water vapour [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Ultraportable Greenhouse Gas Analyzer (UGGA) reports measurements of methane, carbon dioxide and water vapour simultaneously in a package that is compact and crushproof. Small enough to be carried on-board aircraft (TSA approved size) and requiring only 70 watts, within 100 seconds after power-up, and may be operated wirelessly with an iPhone or Tablet.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WAO / FTIR</title>
		<link>https://amof.ac.uk/instruments/wao-ftir/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Wed, 26 Feb 2020 15:35:05 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=2575</guid>

					<description><![CDATA[The Ecotech Spectronus is a state-of-the-art Fourier Transform Infrared Spectrometer (FTIR) that can simultaneously measure [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Ecotech Spectronus is a state-of-the-art Fourier Transform Infrared Spectrometer (FTIR) that can simultaneously measure atmospheric concentrations of carbon dioxide (CO<sub>2</sub>), methane (CH<sub>4</sub>), nitrous oxide (N<sub>2</sub>O) and carbon monoxide (CO).</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WAO / Radon Measurements</title>
		<link>https://amof.ac.uk/instruments/wao-ansto/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Mon, 30 Dec 2019 15:35:45 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=1968</guid>

					<description><![CDATA[The Australian Nuclear Science and Technology Organisations (ANSTO) 1500L low-level radon monitor provides a unique [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Australian Nuclear Science and Technology Organisations (ANSTO) 1500L low-level radon monitor provides a unique technology for highly sensitive measurements of atmospheric radon (&lt; 100 mBq m<sup>-3</sup>) and is recognised by the World Meteorological Organisation (WMO) as the best in the world for global and atmospheric compositional baseline studies.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WAO / O2 and CO2</title>
		<link>https://amof.ac.uk/instruments/wao-sable-systems-oxzilla-ii/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Mon, 30 Dec 2019 15:31:06 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=1958</guid>

					<description><![CDATA[A single gas handling system is used to measure carbon dioxide (CO2) and molecular oxygen [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>A single gas handling system is used to measure carbon dioxide (CO<sub>2</sub>) and molecular oxygen (O<sub>2</sub>) concurrently in a single contiguous system including both analysers.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WAO / Reduction Gas Analyser &#8211; H2 Monitor</title>
		<link>https://amof.ac.uk/instruments/wao-reduction-gas-analyser/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Mon, 30 Dec 2019 15:30:15 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=1956</guid>

					<description><![CDATA[The Reduction Gas Analyser makes quasi-continuous measurements of molecular hydrogen (H2) in atmospheric air.]]></description>
										<content:encoded><![CDATA[<p>The Reduction Gas Analyser makes quasi-continuous measurements of molecular hydrogen (H<sub>2</sub>) in atmospheric air.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WAO / ECD on Clarus 500 Greenhouse Gas Chromatograph &#8211; SF6 Monitor</title>
		<link>https://amof.ac.uk/instruments/wao-ecd-clarus-on-500-greenhouse-gas-chromatograph/</link>
		
		<dc:creator><![CDATA[Barbara Brooks]]></dc:creator>
		<pubDate>Mon, 30 Dec 2019 15:29:44 +0000</pubDate>
				<guid isPermaLink="false">https://amof.ac.uk/?post_type=instruments&#038;p=1955</guid>

					<description><![CDATA[Quasi-continuous measurements of sulphur hexafluoride (SF6) in atmospheric air]]></description>
										<content:encoded><![CDATA[<p>Quasi-continuous measurements of sulphur hexafluoride (SF<sub>6</sub>) in atmospheric air</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CVAO / Picarro CO Monitor</title>
		<link>https://amof.ac.uk/instruments/cvao-picarro-co-monitor/</link>
		
		<dc:creator><![CDATA[Harriett]]></dc:creator>
		<pubDate>Wed, 25 Sep 2019 09:06:42 +0000</pubDate>
				<guid isPermaLink="false">http://amof-ac-uk.stackstaging.com/?post_type=instruments&#038;p=1095</guid>

					<description><![CDATA[Simultaneous, precise measurement of CO, CO2, CH4 , and H2O for lab, field or mobile [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>Simultaneous, precise measurement of CO, CO<sub>2</sub>, CH<sub>4 </sub>, and H<sub>2</sub>O for lab, field or mobile applications.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>COZI / Aero-Laser CO Monitor</title>
		<link>https://amof.ac.uk/instruments/aero-laser-co-monitor/</link>
		
		<dc:creator><![CDATA[Harriett]]></dc:creator>
		<pubDate>Tue, 10 Sep 2019 11:48:27 +0000</pubDate>
				<guid isPermaLink="false">http://amof-ac-uk.stackstaging.com/?post_type=instruments&#038;p=998</guid>

					<description><![CDATA[The AL5001 from Aero-Laser is a fast carbon monoxide (CO) monitor with a unique sensitivity [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The AL5001 from Aero-Laser is a fast carbon monoxide (CO) monitor with a unique sensitivity below 1ppb (parts per billion). The detection of CO is based on a VUV-fluorimetry, employing the excitation of CO at 150nm.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
